Hybrid-operated smart ventilation unit for Fund of civil protection structures MVUS .
(for basic shelters, Fallout shelter, bunkers, multipurpose facilities and Primary
Mobile Shelters(PMU)).
(According to Ministry of Internal Affairs Order No. 579, DBN V.2.2‑5:2023, DSTU 9329:2025)
Technical Specifications of Ukraine (TU U) 28.2‑42487751‑001:2023
(Technical conditions Approved by the State Emergency Service of Ukraine (SESU), ref. №. 94-2586/94-18, dated 12 December 2023)
How does it work?
MVUS can be installed onto an existing or pre-installed air-circulation system, and also become a separate, cost-efficient ventilation unit in case there’s absence of it.
The manually operated fan lets you adjust the supply unit as needed.
MVUS smart installations can be included in the design of major or ongoing renovation projects, or purchased as a complete unit, with installation, logistics, and materials included in the price.
Verified Standards Compliance:
The MVUS smart ventilation unit has obtained all required documentation:
- Testing protocols;
● Declarations of Conformity;
● Technical Specifications(TU);
● Copyright for the Technical Passport and Graphic Materials;
● “SESU Approval of Technical Specifications”
Why MVUS is essential for shelters?
Reliability during blackouts and infrastructure damage
Simple, fast, and cost-effective solution
User-friendly and cost-effective backup
Easy and intuitive to use (even for teenagers)
Dual-purpose: works as primary or backup ventilation.
Our Projects
Select your MVUS option
MVUS 1000 Ventilation System
- Capacity: Up to 100 people
- Room area :100 m²
- Hand-operated fan
- • Sound-isolating frame
- Louver damper
- • Anti-rust coating
- Filtration system
MVUS 2000 Ventilation System
- Capacity: Up to 200 people
- Room area: 200m
- Hand-operated fan
- Sound-isolating frame
- • Louver damper
- • Anti-rust coating
- Filtration system
MVUS 1000-based air handling unit (AHU) with manual and electric drive
- Capacity: Up to 100 people
- Room area: 100 m
- Manually-operated fan
- Ductwork systems
- Air filtration systems, bars, mounts
- Installation and testing(comissioning)
- Exhaust fan
- Electric heater
- Control panel
MVUS 2000-based air handling unit (AHU) with manual and electric drive
- Capacity: Up to 200 people
- Room area: 200 m
- Manually-operated fan
- Ductwork systems
- Air filtration systems, bars, mounts
- Installation and testing(comissioning)
- Exhaust fan
- Electric heater
- • Control panel
Additional options and services:
- Explosion Isolation Valve
- CO2 Level Monitoring Device
- Radiological Protection Filters
- Energy Recovery System(Recuperation)
- Exhaust Fan Configuration Availability(Exhaust Fan Installation Option)
- Technical, Expert and Judicial Dossier Package